worse blow jobs I ever had

the blower motor cylindrical fan on my furnace is the shittiest piece of SHIT THAT WAS EVER A PIECE OF FRICKING SHIT

EVERY YEAR WHEN IT GETS COLD IT SELF DESTRUCTS BECAUSE IT'S A FRICKAIO"HNGDSAN KLJM<M PIECE OF SSHITGSALDKEJHFTRKJ

ME AND QUEERIE BEEN SITTING AROUND HERE CHILLIN LITERALLY FOR LIKE A WEEK AT 50 DEGREES AMERICAN AND I FINALLY GET THE NEW OVERPRICED REPLACEMENT AND THE SHAFT BREAKS OFF IN THE FRICKING MIDDLE FML

NO REFUNDS FROM THIS SHITTY FRICKING SHIT SITE WWW.PARTSSOURCE.COM FRICK THIS SITE.

picture guide:

1- original OEM blower motor fan that exploded like 5 years ago and I overpayed some r-slurred hvac butthole to replace the whole GOT DARN thing. I didn't really even understand what had happened then except I found evidence later that the fan had fricking exploded as there were the fanblades scattered in the bottom of the furnace floor.

https://i.rdrama.net/images/17317240315058892.webp

2- piece of shit replacement OEM spun itself off the shaft nearly destroying the whole case of the new blower motor replacement from year prior and chewed itself to death before any of the so called safety features did shit

https://i.rdrama.net/images/17317240305645669.webp

3- SAME THING AS ABOVE, LASTED 1 YEAR, SHAFTED ITSELF

https://i.rdrama.net/images/17317240324532351.webp

4- PIECE OF FRICKING SHIT REPLACEMENT OEM LITERALLY BROKE FROM THE SHAFT AS I WAS TRYING TO REPLACE IT, SEATED WITH ONLY GENTLE PRESSURE AND THE MIDDLE KEYSLOT SHAFT COMPLETELY TORE OUT FML. GONNA TRY TO SALVAGE WITH EPOXY AS PICTURED USING WASHERS TO TRY AND REINFORCE BUT MY HOPES ARE LOW. I ALREADY ANTICIPATED THIS WAS A GONNA BE A TEMP SOLUTION BUT THE REAL PART FROM AMAZON ISN'T GONNA BE HERE FOR ANOTHER WEEK :marseyraging:

https://i.rdrama.net/images/17317240286986794.webp https://i.rdrama.net/images/17317240296150534.webp

The motor/casing and everything else is LITERALLY FINE and TRUE, is all just this GOT DARN PLASTIC SHIT FAN that refuses to STAY PUT and instead is designed to shit the bed even though I change filters every 4-6 months and use the light filters to reduce wear on the system.

!homeowners wish me luck, if this or the next replacement fails I'm ngmi

:fffffffuuuuuuuuuuuu#:

53
Jump in the discussion.

No email address required.

3d print a new one

But seriously that squirrel cage looks tiny.


https://i.rdrama.net/images/17191743323420358.webp

Jump in the discussion.

No email address required.

the motor literally runs on regular AC power at one speed, on or off, so I'm close to just rigging up my dust blower

https://i.rdrama.net/images/17317252629099638.webp

into the same getup with a few tubes and hose clamps I stg because its basically all metal and uses the same power and should be heat resistant enough to move all the carbon monoxide outside, I think

:marseygas#:

Jump in the discussion.

No email address required.

Is this like a Lennox Pulse furnace or something? Seriously it looks too small to be the whole-house blower

Though measuring mine, it's about 12 inches

https://i.rdrama.net/images/17317264367663863.webp


https://i.rdrama.net/images/17191743323420358.webp

Jump in the discussion.

No email address required.

much smaller, blower wheel is only 4.75 inches

https://i.rdrama.net/images/17317268219487345.webp

Jump in the discussion.

No email address required.

I don't understand. Do you live in an abandoned shack? Is this a purge blower?

I have two camper air conditioners sitting in my garage. Their blowers are 8" in diameter.

https://i.rdrama.net/images/1731727438365965.webp


https://i.rdrama.net/images/17191743323420358.webp

Jump in the discussion.

No email address required.

there's a much larger internal fan that powers the entire setup, this one is just purely for the exhaust from gas heat :marseythumbsup:

Jump in the discussion.

No email address required.

ok good.

then yeah, take a blower or shopvac and hook it up to the vent outside your house


https://i.rdrama.net/images/17191743323420358.webp